Prioritize the guest experience
List reception communications, selected lights, Wi-Fi and other essential equipment. Separate these from water heating, cooking, laundry and large air-conditioning loads.
Plan selected critical loads for guest houses, villas, boutique hotels and accommodation businesses, based on the service you need to maintain during an outage.
Check my load
List reception communications, selected lights, Wi-Fi and other essential equipment. Separate these from water heating, cooking, laundry and large air-conditioning loads.
Record each refrigerator, freezer and pump, including starting-current information. Compressor Starting Current and simultaneous restarts require assessment even when running watts fit below 6 kW.
Check reception hours, meal preparation and overnight requirements. Enter realistic backup hours per item. Do not treat nominal storage as a guaranteed overnight runtime.
Larger hotels need measured demand and a site-specific design before considering whole-building backup. Discuss circuit separation, charging windows and any interruption-sensitive systems with Avrio.
AVPB-6K-8N / LOAD PLANNING
6 kW rated AC output. 8 kWh nominal NMC storage × 80% = 6.4 kWh nominal usable energy before losses. Enter actual electrical input, not cooling capacity. All listed loads are assumed to run together for the continuous-load check.
Actual runtime depends on conversion losses, load cycling, battery condition, operating conditions, charging availability and equipment behavior. Final suitability must be confirmed by Avrio Technologies.